HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
65Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
15. Configure the controllers for multiple-bus failover mode:
SET MULTIBUS_FAILOVER COPY = THIS_CONTROLLER
This command automatically restarts the OTHER controller.
You should see %LFL and %EVL prompts. Refer to the HP StorageWorks HSG80 Array
Controller ACS V8.7 Maintenance and Service Guide for more information on these
reports.
T 16. To ensure that the setting from step 15 has been applied, issue the command:
SHOW OTHER_CONTROLLER FULL
Check the display to verify that the controllers have been configured to support
multiple-bus failover mode. You should see a display similar to that in Example Display 4.
Example Display 4
Controller:
HSG80 ZG8nnnnnnn Software V87P, Hardware E03
NODE_ID = nnnn-nnnn-nnnn-nnnn
ALLOCATION_CLASS = 0
SCSI_VERSION = SCSI-2
Configured for MULTIBUS_FAILOVER with ZG8nnnnnnn
In dual-redundant configuration
Device Port SCSI address 7
Time: NOT SET
Command Console LUN is lun 0 (NOIDENTIFIER)
.
.
.
Note: These settings are applied automatically to the bottom controller (controller B2). It is not
necessary to repeat these steps on controller B2.
T 17. You must select the SCSI mode for the subsystem. Some operating systems support only
one SCSI mode. For more information, refer to the DRM Release Notes.
a. To set SCSI-3 mode:
SET THIS SCSI = SCSI-3
Note: For OpenVMS, set allocation class and identifier:
SET THIS ALLOCATION_CLASS = 1
SET THIS_CONTROLLER IDENTIFIER = 99
Setting this switch causes the host to load the SYS$DRIVER, which provides the GG
devices. The value range is 1 - 99.
D0 (D-zero) can no longer be used as a device LUN in SCSI-3 mode.