HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
68 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
You should see a display similar to that in Example Display 7.
Example Display 7
.
.
.
Host PORT_1:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
. . . . . . . . . . . .PORT_1_TOPOLOGY = FABRIC (connection down)
Address . . . . . . . . . . . . . . . . . . . . . . . . . . .=nnnnnn
Host PORT_2:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
. . . . . . . . . . . .PORT_2_TOPOLOGY = FABRIC (connection down)
Address . . . . . . . . . . . . . . . . . . . . . . . . . . .=nnnnnn
NOREMOTE_COPY
.
.
.
T 25. Enable remote copy functionality:
SET THIS_CONTROLLER REMOTE_COPY=TargetControllerName
Example: set this_controller remote_copy=BuildngB
Note: Be sure to specify a meaningful target controller name
,
such as a name that reflects the
target node’s location. The name can be up to eight characters and must be unique to all of
your controllers
.
Do not use
init, initial, rem,
or
remote
; they are reserved keywords.
After you have issued this CLI command, you see a series of %LFL and %EVL displays;
the controllers automatically restart.
T 26. Verify that these settings are in place:
SHOW THIS_CONTROLLER
You should see a display similar to that in Example Display 8.
Example Display 8
.
.
.
Host PORT_2:
Reported PORT_ID = nnnn-nnnn-nnnn-nnnn
. . . . . . . . . . . . . . . . . . PORT_2_TOPOLOGY = FABRIC (up)
REMOTE_COPY = BuildngB
.
.
.