HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
71Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
Example Display 10
LUN Uses Used by
---------------------------------------------------------------------------
D1 DISK10000
LUN ID: nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn-nnnn
NOIDENTIFIER
Switches:
RUN NOWRITE_PROTECT READ_CACHE
READAHEAD_CACHE WRITEBACK_CACHE
MAXIMUM_READ_CACHED_TRANSFER_SIZE = 128
MAXIMUM_WRITE_CACHED_TRANSFER_SIZE = 128
Access:
NONE
State:
ONLINE to this controller
PREFERRED_PATH = OTHER
Host based logging NOT specified
Size: nnnnnnnn blocks
Geometry (C/H/S): ( 7000 / 20 / 254 )
Cable the Target Site
This section provides instructions for cabling the target site.
Connect Fiber Optic Cables Between Controllers and Fibre Channel Switches
Use your established cabling policy to connect the host to the Fibre Channel switches.
T 1. Make sure that you have installed all required GBICs into each of the Fibre Channel
switches.
T 2. Use 50-micron, multimode fiber optic cable to connect port 1 of the top controller to the
top Fibre Channel switch.
T 3. Use 50-micron, multimode fiber optic cable to connect port 2 of the top controller to the
top Fibre Channel switch.
T 4. Use 50-micron, multimode fiber optic cable to connect port 1 of the bottom controller to
the bottom Fibre Channel switch.
T 5. Use 50-micron, multimode fiber optic cable to connect port 2 of the bottom controller to
the bottom Fibre Channel switch.
Tip: You should see an illuminated green LED on the switch as soon as the cable is inserted at both
ends. This verifies that there is a good connection.