HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
81Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
T 2. When you have completed the worksheet, rename the connections:
RENAME !NEWCONxx TargetHostConnectionNamex
RENAME !NEWCONxx TargetHostConnectionNamey
Example: rename !NEWCONxx HostB1
Example: rename !NEWCONxx HostB2
T 3. Change the operating system for each connection to HP-UX:
SET !NEWCONxx operating_system=hp
T 4. After you have renamed the host connections, issue the following command to see the new
settings:
SHOW CONNECTIONS
Update Switch Zones
The switch zones created earlier must be updated with the host connection information:
T 1. On the top fabric, add the host connection to the zone that contains port 1 of the top target
controller.
T 2. On the bottom fabric, add the host connection to the zone that contains port 1 of the
bottom target controller.
Disable Access to the Hosts at the Target Site
T To prevent the target hosts from writing to any remote copy set targets, access must be
disabled:
SET UnitName DISABLE=ALL
Repeat for each unit.
Note: This step is for remote copy set LUNs only.
Install the Secure Path Fibre Channel HBA Device Driver
T Install the Secure Path Fibre Channel HBA device driver according to the instructions in the
current version of the HP StorageWorks Secure Path for HP-UX Installation and Reference
Guide.
Verify the Disks
T Verify that the nonremote copy set disks are present by issuing the following command:
ioscan -fnCdisk
The output should be similar to that shown in Example Display 16.