HP StorageWorks Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide (AA-RPHZF-TE, March 2004)

Configuring a Standard Data Replication Manager Solution
86 Data Replication Manager HSG80 ACS Version 8.7P Configuration Guide
T 4. Back up all Volume Groups (highly recommended).
T 5. Unmount and perform file system check on all logical volumes, varyoff, and export
volume groups, with the following commands:
#umount /dev/(logical_volume_name)
#fsck /(file_system_name)
#varyoffvg (volume_group_name)
T 6. Remove all hdisks associated with DEC HSG80 RAID array from the configuration
database with the following commands:
#lsdev -Cc disk
#rmdev -dl hdiskx (x is the hdisk number)
T 7. Remove all Fibre Channel adapters from the configuration database with the following
commands:
#lsdev -Cc adapter
#rmdev -dl scsix
(x is the Cambex adapter number)
T 8. Uninstall the Fibre Channel driver with the following command:
#installp -u PC1000.driver.obj
T 9. Disconnect all Fibre Channel adapter cables.
T 10. If adding an additional Cambex Fibre Channel adapter, shut down the server with the
following command:
#shutdown
T 11. Install additional Fibre Channel HBAs (if required). Do not connect fiber cables at this
time.
Note: The maximum number of HBAs per host is 6. Refer to IBM's PCI Adapter Placement
Reference document.
T 12. Power up or boot server.
T 13. Load StorageWorks HSG80 ACS Version 8.7 platform kit for AIX:
a. Load platform CD into CD drive.
b. Enter the following commands:
#mkdir /cdrom
#mount -v cdrfs -r /dev/cd0 /cdrom
#cd /cdrom
#./INSTALL
(follow the prompts)
The system will not find any DEC HSG80 RAID array devices at this time.