HP StorageWorks File System Extender Software V3.4 CLI reference (T3648-96013, October 2006)

2.4 NAME 29
–m, –fsc–media
Perform a consistency check on the FSE partition PartitionName comparing
the corresponding File System Catalog against the associated FSE media.
For details on this process, see section CHECKING FILE SYSTEM CAT-
ALOG CONSISTENCY.
–autocorrect
Automatically correct errors discovered by the consistency check of File
System Catalog against corresponding FSE media. For details on this pro-
cess, see section CHECKING FILE SYSTEM CATALOG CONSIS-
TENCY. This option can only be used in combination with the –fsc–
media option.
–match–media
Correct the errors by removing the entries that have been found only in the
File System Catalog and not in the Fast Recovery Information blocks on the
FSE media. This type of correction further synchronizes the FSC content
with the data actually present on the media. For details on this process,
see section CHECKING FILE SYSTEM CATALOG CONSISTENCY.
This option can only be used in combination with the –autocorrect option.
–B, –barcode
Perform a consistency check on the FSE partition PartitionName comparing
corresponding File System Catalog against the FSE media specified in the
Barcode argument. For details on this process, see section CHECKING
FILE SYSTEM CATALOG CONSISTENCY. This option can only be
used in combination with the –fsc–media option.
Barcode...
A sequence of identifiers of the FSE media that are being checked. In most
cases, identifiers are numerical barcodes. With disk media, identifiers are
relative parts of the disk media mount points (for example: dm_001, dm_-
002). Note that the following limitations apply:
media that are unavailable will not be processed.
media that are specified in the command line must belong to the same
FSE partition. In the opposite case, the fsecheck command will fail.