HP StorageWorks File System Extender Software V3.4 CLI reference (T3648-96013, October 2006)

2.7 NAME 50
is not running, start it with the fse – –start command. There should also be a Par-
tition Manager process (fse–pm) running for FSE partition for which the jobs are
monitored. This can be checked with the fsesystem and fsepartition commands.
After successful command execution fsejob notifies the FSE administrator with
a suitable message, which is printed to the standard output stream (stdout). If
there was an error during the command execution, an appropriate error message
is printed to the standard error stream (stderr).
JOB LIST INFORMATION Job information that is displayed using the –list
option is the following:
1. JobID .......... job identification number (JobID),
2. Partition .......... name of the FSE partition on which the job is running,
3. Type .......... job type (migration, recall, admin, maintenance, reorg, recov-
ery, backup, unknown),
4. Priority .......... current job priority,
5. Started .......... job starting date and time in the format of YYYY/MM/DD
hh:mm:ss,
6. Status .......... current job status (phase).
... A numerical value is shown for jobs which are in phase of waiting for free re-
sources and a "n/a" string for jobs which already allocated the required resources.
The job id is a numerical identification of a job that consists of the start date of
the job and its sequence number for that particular day.
JOB STATUS INFORMATION Job status information that is printed using
the –status option consists of two parts. First part is the same information as
reported by the –list option, in this case laid out in rows rather than in columns.
For description of the reported data, see section JOB LIST INFORMATION.
Second part consists of one or more lines, each with the following information:
1. Copy .......... consecutive number of migrated data copy,
HP StorageWorks File System Extender Software CLI reference