FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
2-76
Enterprise Operating System Command Line Interface User Manual
config
Parameters This command has one parameter.
Command Example
Root> config switch priority principal
config.switch.raTOV
Syntax raTOV timeoutValue
Purpose This command sets the R_A_TOV for the switch.
NOTE: The switch must be set offline before this command is entered.
Special care should be used when scripting this command due to its
relationship with E_D_TOV.
Priority Specifies the switch priority. Valid values are:
principal, default, or neverprincipal.
principal — sets the numerical switch priority
to 1. The switch with a priority of 1 becomes the
principal switch; however, if two or more
switches have a priority of 1, the switch with
the lowest WWN becomes the principal switch.
default — sets the numerical switch priority
to 254. If no switch is set to principal, the switch
with a priority 254 becomes the principal
switch; however, if two or more switches have a
priority of 254, the switch with the lowest
WWN becomes the principal switch.
neverprincipalsets the numerical switch
priority to 255. This switch is not able to become
the principal switch.
At least one switch in a multiswitch fabric must
have a switch priority value of principal or
default.
The number codes 2–253 are not now in use.