FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
CLI Commands
2-85
config
NOTE: Port numbers cannot be used for zone members if the interoperability
mode for the switch or director is set to Open Fabric 1.0 mode. In this case,
you must use node WWNs as zone members.
NOTE: A Sphereon 4300 Switch cannot participate in a fabric, unless the
Fabric Capable feature is enabled. For more information, see the McDATA
Sphereon 4300 Switch Installation and Service Manual (620-000171).
Table 2-1 shows the limits for configuring zoning in McDATA fabrics
that are supported by switch and director firmware as of 11/14/03.
Although EFCM 8.0 or EFCM 8.0b may allow you to configure
greater values in the Zoning Library, values in this table have been
tested and are supported. For the latest limits, refer to the Supported
Fabrics Configuration Document located on www.mcdata.com in the
Resource Library or contact your customer support representative.
config.zoning.activateZoneSet
Syntax activateZoneSet
Purpose This command activates the zone set contained in the work area to
the fabric and takes effect immediately.
NOTE: This command takes effect immediately in the fabric.
Parameters This command has no parameters.
Command Example
Root> config zoning activateZoneSet
Table 2-1 Supported Zoning Configurations
Product
Intrepid 6064
Intrepid 6140
Sphereon 4500
Sphereon 3x32
Sphereon 3x16
ED-5000
Number of End Ports 1024 1024 1024 1024
Unique Zone Members 1024 1024 1024 1024
Members per Zone 1024 1024 1024 1024
Zones 1024 1024 1024 512