FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
CLI Commands
2-87
config
config.zoning.addWwnMem
Syntax addWwnMem zoneName wwn
Purpose This command adds a WWN zone member to the specified zone in
the work area.
NOTE: A product can have at most 1024 zone members in its zones.
NOTE: The ED-5000 supports a maximum of 512 zones.
Parameters This command has two parameters.
Command Example
Root> config zoning addWwnMem TheUltimateZone
10:00:00:00:C9:22:9B:64
config.zoning.addZone
Syntax addZone zoneName
Purpose This command adds a new (empty) zone to the zone set in the work
area.
NOTE: Changes are not activated on the switch until the
config.zoning.activateZoneSet command is issued.
NOTE: A zone set can have a maximum of 1024 zones.
NOTE: A Switch or Director can have a maximum of 1024 zone members in
all of its zones, except for the ED-5000, which allows a maximum of 512
zones.
zoneName Specifies the name of the zone.
wwn The WWN of the member to be added to the
zone. The value of the WWN must be in
colon-delimited hexadecimal notation (for
example, AA:00:AA:00:AA:00:AA:00).