FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
CLI Commands
2-145
show
Output The event log data are displayed as a table that includes the following
properties.
Output Example The output from the show.eventLog command displays as follows.
Date/Time Code Severity FRU Event Data
---------------- ---- -------- ----- -----------------------------------
04/12/01 10:58A 375 Major CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/12/01 9:58A 385 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
04/11/01 7:18P 395 Severe CTP-0 00010203 04050607 08090A0B 0C0D0E0F
show.fabricLog.noWrap
Syntax noWrap [clear]
Purpose This command allows the user to view the contents of the
non-wrapping region of the fabric log. The log entries will not persist
IMLs or power cycles; it will not be stored in NV RAM.
NOTE: This log will not wrap. The log will stop collecting entries after is it
filled.
Date/Time The date and time when the event occurred.
Code The event reason code.
Severity The severity of the event. The values are:
Major—Unit operational (major failure).
Minor—Unit operational (minor failure).
Severe—Unit not operational. The causes are
either that the switch contains no operational
SBAR cards or that the system shuts down
due to CTP thermal threshold violations.
Info—Unit operational (information only).
FRU The FRU and FRU position, where applicable.
Event Data The 32-byte hexadecimal description of the
event in words.