FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
CLI Commands
2-175
show
Attached WWN The WWN of the device or switch attached to
the port, if one is attached.
Beaconing The beaconing state for the port (Off or On).
Reason An optional message number that indicates if
the port has a segmented ISL, if a port binding
violation has occurred, or if the port is inactive.
The message description for this message
number is provided at the bottom of the table.
If the operational state is Segmented E_Port, only
the following messages can be generated:
•01: Segment Not Defined
02: Incompatible Operating Parameters
03: Duplicate Domain ID(s)
04: Incompatible Zoning Configurations
05: Build Fabric Protocol Error
06: No Principal Switch
07: No Response from Attached Switch
08: ELP Retransmission Failure Timeout
If the operational state is Invalid Attachment only
the following messages can be generated:
•09: Unknown
10: ISL connection not allowed on this port
11: ELP rejected by the attached switch
12: Incompatible switch at other end of the ISL
13: External loopback adapter connected to the
port
14: N_Port connection not allowed on this port
15: Non-McDATA switch at other end of the ISL
16: ISL connection not allowed on this port
17: ISL connection not allowed to external Fabrics
18: Port binding violation - unauthorized WWN
19: Unresponsive Node Connected to Port
20: Incompatible security attributes
21: Fabric Binding violation
22: Authorization failure
23: Switch Binding violation