FW 07.00.00/HAFM SW 08.06.00 McDATA Enterprise Operating System Command Line Interface User Manual (620-000134-720, April 2005)

Table Of Contents
2
CLI Commands
2-13
config
Parameters This command has four parameters.
NOTE: The interval value is a fixed length amount of time. This interval is
not a rolling window interval.
name The name of the fencing policy.
typeNumber This must be entered as a number that
corresponds to an entry in the table
shown below.
limit The count of fencing violations that must
occur within the specified period in order
for a port to be automatically disabled.
Acceptable values are in the range of
1-255.
You may also enter default for this
argument, which will set the default limit
value for this fencing policy type.
period The number of seconds in which the
violation count must equal or exceed the
threshold limit in order for a port to be
fenced.
You may also enter default for this
argument, which will set the default
period for this fencing policy type.
Type
Number
Policy Type
Default Limit
Value
Default Period Value
1 Protocol Errors 5 300 seconds
Type
Number Policy Type Limit Value Range Period Value Range
1 Protocol Errors 1 - 255 60 - 1800 seconds