FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

3
3-26
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Diagnostics
Is a link incident or port problem indicated for any of the ports?
NO YES
A link incident problem or port SFP failure is indicated. Go to
step 52 to obtain event codes. If no event codes are found,
go to MAP 0600: Port Failure and Link Incident Analysis on
page 3-72.
50
Inspect the power supply operational states.
a. At the View panel, click the Component Properties tab. The View
panel (Component Properties tab) displays.
b. Inspect the State fields for both power supplies.
Does the State field display a Failed message for either power
supply?
NO YES
A power supply failure is indicated. Go to step 52 to obtain event
codes. If no event codes are found, go to MAP 0100: Power
Distribution Analysis on page 3-28.
51
Inspect the State fields for Fan 0, and Fan 1 through Fan 3.
Does the State field display a Failed or Not Installed message for
any of the fans?