Task 25: Configure the Switch from the SANpilot Interface (Optional)
2-115
Installation Tasks
2. At the Operations panel, select the Configure option at the left side
of the panel. The Configure panel opens with the Ports page
displayed.
3. At the Configure panel, click the Switch tab, then click the
Fabric Parameters tab. The Switch page displays with the Fabric
Parameters tab selected (Figure 2-93).
Figure 2-93 Configure Panel (Director Page with Fabric Parameters Tab)
a. At the R_A_TOV field, type a value between 10 through 1200
tenths of a second (one through 120 seconds). Ten seconds
(100) is the recommended value.
NOTE: If the switch is attached to a fabric element, the switch and
element must be set to the same R_A_TOV value. If the values are not
identical, the E_Port connection to the element segments and the
switch cannot communicate with the fabric. In addition, the
R_A_TOV value must be greater than the E_D_TOV value.
b. At the E_D_TOV field, type a value between 2 through 600
tenths of a second (0.2 through 60 seconds). Two seconds
(20) is the recommended value.