McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
Repair Information
.
Figure 4-3 Sphereon 3032 and 3232 Event Log
The log contains the following columns:
Date/Time - the date and time the switch event occurred.
Event - the three-digit event code associated with the event. Refer
to Appendix B, "Event Code Tables"for an explanation of event
codes.
Description - a brief description of the event.
Severity - the severity of the event (Informational, Minor, Major, or
Severe).
FRU-Position - an acronym representing the FRU or non-FRU
elements, followed by a number representing the FRU or chassis
position. The acronyms are:
SFP - Small form factor pluggable (SFP) optical transceiver.
Chassis slots for SFPs inserted in a port are 0 through 31. SFPs
are FRUs.
PWR - power supply. Chassis slots for redundant power
supplies are 0 and 1. Power supplies are FRUs.
FAN - cooling fan. Chassis slots for redundant fans are 0
through 3. Fans are FRUs.
CTP - control processor (CTP) card. The chassis slot is 0. The
CTP card is not a FRU.
THM - thermal sensor. The chassis slot is 0. The thermal
sensor is not a FRU.
Event Data - up to 32 bytes of supplementary event data (if
available for the event) in hexadecimal format. Refer to Appendix
B, "Event Code Tables"for an explanation of the supplementary