FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

4
Using Views
4-17
Repair Information
Online, offline, or testing.
—Beaconing.
Invalid Attachment.
Link incident or link reset
No light, not operational, or port failure.
—Segmented E_Port.
Type - The type of port. Valid port types are a generic port
(G_Port) that is not connected to a Fibre Channel device or
switch, therefore light is not transmitted; fabric port (F_Port) that
is connected to a device; or an expansion port (E_Port) that is
connected to another switch to form an interswitch link (ISL).
Alert - If link incident (LIN) alerts are configured for the port
through the Configure Ports dialog box, a yellow triangle appears
in the column when a link incident occurs. A yellow triangle also
appears if beaconing is enabled for the port. A red and yellow
diamond appears if the port fails.
Click anywhere in the port row to open the Port Properties dialog box.
Right-click anywhere in the port row to open a pop-up menu to:
•Open the Port Properties dialog box.
•Open the Node Properties dialog box.
•Display the Port Technology dialog box.
Block or unblock the port.
Enable port beaconing.
Perform port diagnostics.
Enable or disable port channel wrapping. This menu option
appears only when the switch is configured for FICON
management style.
Swap one Fibre Channel port address with another. This menu
option appears only when the switch is configured for FICON
management style.
Clear link incident alerts.
Reset the port.
Configure Port Binding.