FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

5
5-10
McDATA® Sphereon 3032 and 3232 Fabric Switches Installation and Service Manual
FRU Removal and Replacement
1. At the hardware view, select firmware library from the
maintenance icon and verify that the firmware version is
the same as that running on the existing fabric. The active
version is displayed at the bottom of the display. To
upgrade/download the active version, select the correct
version and select SEND. The firmware will load, perhaps
taking up to 10 minutes.
Configure the ports the same as the failed switch (select ports
from the configure menu).
Configure SNMP traps, CLI, EWS the same as the failed
switch.
Set the date and time.
Set zoning configuration:
1. At the EFCM product view, select fabric. Select the new
switch icon, then zone set tab.
2. Verify that the active zoneset is the same active zoneset
that is running on the fabric, and that the default zone is
disabled.
3. Add the switch to the fabric:
Connect the fibre-optic cables to the switch ports.
Set the switch online.
Verify that the switch successfully joins the fabric.