FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

B
B-40
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 440
Message: Embedded Port hardware has failed
Severity: Major
Explanation: The embedded port hardware detected an error.
Action: Replace the switch. Perform a data collection operation for the switch using the EFC Manager, and return the
failed CTP card and the CD to McDATA for analysis and repair.
Event Data: Byte 0 = Slot Position
Byte 1 = Reason Code
00 = TX clock loss
01 = Solicited response parity error detected
02 = Solicited response invalid error detected
03 = High availability error threshold exceeded
Bytes 4 - 7 = Elapsed millisecond tick count
Bytes 8 - 11 = High availability error callout (internally defined)
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔