FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

B
Port Module Events (500 through 599)
B-59
Event Code Tables
Event Code: 510
Message: SFP optics hot-insertion initiated
Severity: Informational
Explanation: The hot insertion of a Small Form Factor pluggable optics transceiver has been detected. If the amber LED stays
illuminated after the insertion of the new optic transceiver, see the Port Failure event (506).
Action: No action required.
Event Data: Byte 0 = Slot position (port number)
Bytes 4-7 = Elapsed millisecond tick count.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔
Event Code: 512
Message: SFP optics nonfatal error
Severity: Minor
Explanation: A Small Form Factor pluggable optics module nonfatal failure has been detected by the system software.
Action: Replace the Small Form Factor optics module with a working module of the same type.
Event Data: Byte 00 = Port number (00-8F)
Byte 01 = Reason code
00 = Read of VPD data from optic component failed
Bytes 04-07 = Elapsed millisecond tick count
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔