FW 07.00.00/HAFM SW 08.06.00 McDATA SANpilot User Manual (620-000160-230, April 2005)

B
B-76
McDATA® Sphereon 3032 and 3232 Installation and Service Manual
Event Code Tables
Event Code: 810
Message: High temperature warning (CTP thermal sensor)
Severity: Major
Explanation: The CTP thermal sensor has detected that the "warm" temperature threshold level has been surpassed.
Action: Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔
Event Code: 811
Message: Critically hot temperature warning (CTP thermal sensor)
Severity: Major
Explanation: The CTP thermal sensor has detected that the "hot" temperature threshold level has been surpassed.
Action: Perform the data collection procedure for this switch using the EFC Manager, save the data file to the EFC Zip
drive, and return the CD to McDATA for analysis. Perform a system power-on reset. If the problem persists,
replace the switch.
Event Data: No supplementary data included with this event.
Distribution: Switch EFC Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
✔✔✔✔✔✔