HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Event Reporting Templates
155HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
Disk Transfer Error Event Sense Data Response template
(Template 51)
The controller device services and value-added services software components
report errors detected while performing work related to disk (including CD-ROM
and optical memory) device transfer operations through the Disk Transfer Error
Event Sense Data Response (see Table 46). If an error occurred during the
execution of a command issued by an array controller software component, the
error is signaled to all host systems on the logical unit associated with the physical
unit that reported the error.
ASC and ASCQ codes (byte offsets 12 and 13) are detailed in the “ASC,
ASCQ, Repair Action, and Component Identifier Codes” chapter that starts
on page 161.
Instance Codes (byte offsets 32–35) are detailed in theInstance Codes
chapter that starts on page 177.
Table 46: Template 51—Disk Transfer Error Event Sense Data Response
Format
offset
bit
7 6 5 4 3 2 1 0
0–17 Standard sense data
18–19 Reserved
20 Total number of errors
21 Total retry count
22–25 ASC and ASCQ stack
2628 Device locator
29–31 Reserved
3235 Instance Code
36 Template
37 Template flags
38 Reserved
39 Command OpCode
40 Sense data qualifier
41–50 Original CDB
51 Host ID
52–53 Reserved
54–69 Controller board serial number
70–73 Controller software revision level