HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Last Failure Codes
231HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
02EE0102 A CLD is already allocated when it should be free:
Last failure parameter [0] contains the requesting entity.
Last failure parameter [1] contains the CLD index.
01
02EF0102 A CLD is free when it should be allocated:
Last failure parameter [0] contains the requesting entity.
Last failure parameter [1] contains the CLD index.
01
02F00100 The controller has insufficient free resources for the configuration restore
process to obtain a facility lock.
01
02F10102 The configuration restore process encountered an unexpected nonvolatile
parameter store format. The process cannot restore from this version:
Last failure parameter [0] contains the version found.
Last failure parameter [1] contains the expected version.
01
02F20100 The controller has insufficient free resources for the configuration restore
process to release a facility lock.
01
02F34083 A device read operation failed during the configuration restore
operation. The controller is crashed to prevent possible loss of saved
configuration information on other functioning devices:
Last failure parameter [0] contains the disk port.
Last failure parameter [1] contains the disk target.
Last failure parameter [2] contains the disk LUN.
40
02F44083 The calculated error detection code on the saved configuration
information is bad. The controller is crashed to prevent destruction of
other copies of the saved configuration information. Remove the device
with the bad information and retry the operation:
Last failure parameter [0] contains the disk port.
Last failure parameter [1] contains the disk target.
Last failure parameter [2] contains the disk LUN.
40
Table 56: Last Failure Codes and Repair Action Codes (Sheet 18 of 55)
Last
Failure
Code
Description
Repair
Action
Code