HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide (EK-G80TS-SA. C01, March 2005)

Troubleshooting Information
38 HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide
nllmlml 35 An unexpected bugcheck
occurred during Last
Failure processing.
Last failure processing
interrupted by another last
failure event.
Reset controller.
nllmllm 36 Hardware-induced
controller reset
expected and failed.
Replace controller.
nllmlll 37 Software-induced
controller reset
expected and failed.
Replace controller.
nlllmmm 38 Controller operation
halted.
Last Failure event required
termination of controller
operation, for example:
SHUTDOWN through the CLI.
Reset controller.
nlllmml 39 NVPM configuration
inconsistent.
Device configuration within the
NVPM is inconsistent.
Replace controller.
nlllmlm 3A An unexpected NMI
occurred during Last
Failure processing.
Last Failure processing
interrupted by an NMI.
Replace controller.
nlllmll 3B NVPM read loop hang
occurred.
Attempt to read data from
NVPM failed.
Replace controller.
Table 6: Solid OCP Pattern Displays and Repair Actions (Sheet 4 of 5)
Pattern
OCP
Code
Error Repair Action