HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Release Notes (AA-RV1YA-TE, March 2005)

Host Operating System Notes
45HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for
Windows NT, Windows 2000, and Windows Server 2003 (32-bit) Release Notes
The resulting display should appear similar to the following:
Connection Unit
Name Operating system Controller Port Address Status Offset
!NEWCON68 WINNTVMSTRU64_UNIX OTHER 2 021900 OL other 0
HOST_ID=2000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
!NEWCON69 WINNTVMSTRU64_UNIX THIS 1 021900 OL this 0
HOST_ID=2000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
!NEWCON70 WINNTVMSTRU64_UNIX THIS 1 011800 OL this 0
HOST_ID=2000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
!NEWCON71 WINNTVMSTRU64_UNIX OTHER 2 011800 OL other 0
HOST_ID=2000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01A-A1 WINNTVMSTRU64_UNIX THIS 1 011800 offline 20
HOST_ID=1000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01A-B2 WINNTVMSTRU64_UNIX OTHER 2 011800 offline 20
HOST_ID=1000-0000-C921-4D3D ADAPTER_ID=1000-0000-C921-4D3D
W2K01B-A2 WINNTVMSTRU64_UNIX THIS 1 offline 20
HOST_ID=1000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
W2K01B-B1 WINNTVMSTRU64_UNIX OTHER 2 offline 20
HOST_ID=1000-0000-C920-A562 ADAPTER_ID=1000-0000-C920-A562
W2K02A-A1 WINNTVMSTRU64_UNIX THIS 1 021800 OL this 40
HOST_ID=1000-0000-C921-4F5E ADAPTER_ID=1000-0000-C921-4F5E
2. Note the WWNs of the ADAPTER_ID of the new connections.
3. Find the offline connections with the same ADAPTER_ID WWNs and note
the unit offsets.
4. Type the following command to get a list of all storage units and the host
connections whose access is enabled:
HSGA> SHOW UNIT FULL
5. Type the following commands for:
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #1>
HSGA> SET <unit name> DISABLE_ACCESS=<offline host connection
name #2>
...