HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
102 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Shutting down the subsystem
Use the following steps to shut down a subsystem:
1. Connect a PC or terminal to the maintenance port of one of the subsystem
array controllers.
2. From a host console, stop all host activity to the array controllers and
dismount the logical units in the subsystem.
3. If you are using a Windows NT or Windows 2000 platform, shut down
the server.
4. Shut down the array controllers:
In single-controller configurations, shut down “this controller”
with the following command:
SHUTDOWN THIS_CONTROLLER
In dual-redundant controller configurations, shut down the “other
controller” first, then shut down “this controller” with the
following commands:
SHUTDOWN OTHER_CONTROLLER
SHUTDOWN THIS_CONTROLLER
Note: After the array controllers shut down, the Reset buttons and the first three LEDs
on the OCP turn on (see Figure 38). This process takes several minutes, depending on
the amount of data that needs to be flushed from the cache modules.
5. Proceed only after the Reset buttons and the first three LEDs stop flashing
and remain solid.
Figure 38: OCP Reset button and first three LEDs
1 Reset button
2 First three LEDs
123456
5021