HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
115HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Enter the following CLI command from the controller prompt to save the
current device configuration for “this controller” if the disk was
initialized with the SAVE_CONFIGURATION switch:
CONFIGURATION SAVE
6. Shut down “this controller” with the following command:
SHUTDOWN THIS_CONTROLLER
Note: After the controller shuts down, the Reset button and the first three LEDs turn on
(see Figure 45). This process can take several minutes, depending on the amount of
data that needs to be flushed from the cache module. Proceed only after the Reset
button stops flashing and remains on.
Figure 45: Controller LEDs and Reset button
Caution: The cache module might contain unwritten data if the controller
becomes inoperable and it is not shut down with the SHUTDOWN
THIS_CONTROLLER command. Loss of data could occur.
1 Reset button
2 First three LEDs
123456
5021
1
2