HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
125HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 54: Slot Designations screen for controllers in M2100 and M2200 enclosures
e. Ensure that the program card was removed from the controller to be
replaced. Do not proceed until it is removed.
f. Enter Y(es) to confirm the intent to remove the “other controller.”
Caution: Wait for
FRUTIL
to quiesce the device ports—indicated by an All
device ports quiesced message. Failure to allow the ports to quiesce
can result in data loss. Quiescing can take several minutes.
Note: After the ports quiesce, a countdown timer allows you a total of 2 minutes to
remove the controller. After 2 minutes, the operational controller exits
FRUTIL
and
resumes operations. If this happens, return to step 4 on page 123 and proceed.
5. For the controller to be replaced, complete the following substeps:
Caution: For fiber optic cables without extender clips, use thin needle-nose
pliers to remove the cable from the controller to prevent damaging the cable.
a. Disconnect all host bus cables from the controller being removed.
b. Disengage both controller retaining levers, and then remove the
controller from the enclosure (see Figure 47 on page 117).
c. Place the controller in an antistatic bag or on a grounded antistatic
mat.
Slot Designations M2100/M2200
(back view)
[ Port1 ] [ Port3 ] [ Port5 ]
[ Port2 ] [ Port4 ] [ Port6 ]
[ --------- Controller A -------- ]
[ --------- Controller B -------- ]
[ Cache Module A ] [ Cache Module B ]