HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
127HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
c. Start FRUTIL by entering the following command:
RUN FRUTIL
d. Enter N(o) to the question about replacing the cache battery.
The FRUTIL Main Menu is displayed.
e. Enter option 2 to install a controller or cache module.
If both the controller and cache are missing, the Install Options
screen is displayed (see Figure 55).
Figure 55: Install Options screen
f. Enter option 4 to exit FRUTIL, and then proceed to theInstalling
cache modules in dual-redundant controller configurations” section
that starts on page 142 if both the controller and cache modules have
been removed. Otherwise, continue to the next substep.
g. Enter Y(es) to confirm the intent to install the “other controller.
FRUTIL quiesces the device ports and displays a message indicating
that the controller is being installed.
Caution: Wait for
FRUTIL
to quiesce the device ports—indicated by an All
device ports quiesced message. Failure to allow the ports to quiesce
can result in data loss. Quiescing can take several minutes. The length of time
is dependent on the amount of I/O activity and the number of units that are
online.
Install Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
NOTE: OPTION 1 DISABLED (So: Do cache, then controller.)
Enter choice: 1,2,3,4 ->