HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
128 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: If
FRUTIL
times out before a replacement controller is installed, restart
FRUTIL
.
\
H 2. For the replacement controller, complete the following substeps:
H a. Remove the program card in the replacement controller if it is
installed.
H b. Insert the replacement controller (without the program card installed)
into the appropriate bay, and engage the controller retaining levers.
H c. Press and hold the Reset button, insert the program card, and
continue holding the Reset button.
H d. Press and hold the replacement controller Port #5 button, release the
Reset button, and continue holding the Port #5 button for an
additional 5 to 20 seconds (see Figure 45 on page 115).
The nonvolatile memory in the replacement controller is updated, and
the controller halts with an LED code of 33. Port LEDs 1, 2, 5, and 6
are on (see Figure 45 on page 115).
H e. Press and release the Reset button.
The replacement controller restarts normally.
H f. Wait at least 15 seconds after releasing the Reset button, and then
immediately complete substep 3a below. Be sure to wait 15 seconds
before continuing to substep 3a.
Note: A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing Reset button.