Replacing BA370, M2100 & M2200 Enclosure Elements
130 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
H 4. For the replacement controller, complete the following substeps:
H a. Connect a PC or terminal to the maintenance port of the replacement
controller.
H b. Perform the following:
H i. Set the terminal baud rate to 9600.
H ii. Press Enter or Return several times to get a prompt.
H iii. Proceed to the next substep.
H c. Verify that the controller restarts in the following reset configuration
by entering the following command:
SHOW THIS_CONTROLLER
H Verify that the controller prompt displays HSG>.
H Verify that the NODE_ID is 0000-0000-0000-0000.
H Verify that mirrored cache matches the original configuration.
H Verify that the controller cache is good. See Table 14 through
Table 17 in the “Controller and Cache Replacement
Troubleshooting” appendix that starts on page 253 if the cache is
not good.
Caution: Failure to clear an invalid cache message (especially a Cache is
FAILED message) in substep 4c
before
setting the Failover mode can result in
a recursive bugcheck condition that renders the controller unusable.
H d. Disconnect the PC or terminal from the maintenance port of the
replacement controller.