HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
132 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
6. Disconnect the PC or terminal from the controller maintenance port of the
operational controller.
H 7. Connect the host bus cables to the replacement controller.
H 8. Install the program card ESD cover on the controller being replaced.
Replacing cache modules
Replacing a cache module involves transferring the cache memory DIMMs from
the failed cache module to the replacement cache module. Use the procedures in
this section to replace a cache module in either single or dual-redundant controller
configurations.
Note: With ACS V8.8-
x
,
FRUTIL
prohibits you from installing both the controller and
cache module in one process.
This section contains the following topics:
Replacing cache modules in single-controller configurations, page 134
Replacing cache modules in dual-redundant controller configurations,
page 138
Note: In dual-redundant configurations, both cache modules
must
contain the same
memory configuration, regardless of the ACS version.