Replacing BA370, M2100 & M2200 Enclosure Elements
143HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: If you are installing a cache module after resolving a failed cache issue (see
Table 14 through Table 16 of the Controller and Cache Replacement
Troubleshooting” appendix that starts on page 253), the operational controller and
the replacement controller references that appear in this section may have been
reversed. The operational controller is the one attached to the terminal or PC and the
one from which
FRUTIL
is executed.
H 1. For the replacement cache module, insert each DIMM straight into the
appropriate slot of the replacement cache module (Figure 58 on
page 136), ensuring that the notches in the DIMM align with the tabs in
the slot. Use the following substeps to install the DIMMs:
H a. Press the DIMM gently into the slot until it is seated at both ends.
H b. Engage the two retaining clips for the DIMM.
H c. Ensure that both ends of the DIMM are firmly seated in the slot and
both retaining clips engage the DIMM.
H d. Repeat substep 1a through substep 1c above for each DIMM.
2. For the operational controller, complete the following substeps:
a. Connect a PC or terminal to the operational controller, if not already
connected.
Note: The controller connected to the PC or terminal becomes “this controller.” The
controller for the replacement cache module becomes the “other controller.
b. Start FRUTIL by entering the following command:
RUN FRUTIL
c. Enter N(o) to the question about replacing the cache battery.
d. From the FRUTIL Main Menu, enter 2 for the Install a controller
or cache module option.