HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
147HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
H c. Clear invalid or failed cache conditions, if any exist. See Table 14
through Table 16 in the “Controller and Cache Replacement
Troubleshooting” appendix that starts on page 253 for more
information on clearing invalid or failed cache conditions.
Caution: Failure to clear an invalid cache message (especially a Cache is
FAILED message)
before
setting the Failover mode can result in a recursive
bugcheck error message that renders the controller unusable.
H d. Disconnect the PC or terminal from the maintenance port of the
controller associated with the replacement cache module.
9. For the operational controller, complete the following substeps:
a. Connect a PC or terminal to the maintenance port.
Caution: In substep 9b below, entering the appropriate SET command is
critical. Enabling an incorrect Failover mode can cause loss of data and incur
system downtime.
Verify the original failover configuration, and use the appropriate SET
command to restore this configuration.
b. Re-establish the previous Failover mode by entering one of the
following commands:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER
COPY=THIS_CONTROLLER
Note: After you enter the appropriate SET command, the controller restarts. A
controller restart can take as long as 60 seconds, indicated by the temporary cycling
of the port LEDs and a flashing Reset button.
The SET command copies the subsystem configuration from “this
controller” to the “other controller.”