HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
160 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
b. Insert the replacement PVA and engage both retaining levers.
11. Press Enter or Return to resume device port activity, and then restart the
“other controller.”
Note: A controller restart is indicated by the temporary cycling of the port LEDs and a
flashing Reset button.
12. If the “other controller” did not restart, press the Reset button on the “other
controller.”
13. Enable Failover and re-establish the dual-redundant configuration with one of
the following commands:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from “this controller” to
the “other controller.”
14. If desired, verify the failover configuration with the following command:
SHOW THIS_CONTROLLER FULL
15. Disconnect the PC or terminal from the controller maintenance port.