HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
164 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: If the “other controller” did not restart, press the Reset button.
9. Enable Failover and re-establish the dual-redundant configuration with one of
the following commands:
SET FAILOVER COPY=THIS_CONTROLLER
or
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
This command copies the subsystem configuration from “this controller” to
the “other controller.”
10. If desired, verify the failover configuration with the following command:
SHOW THIS_CONTROLLER FULL
11. Disconnect the PC or terminal from the controller maintenance port.