HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Replacing BA370, M2100 & M2200 Enclosure Elements
165HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Handling a failed DIMM
If a DIMM fails, ACS displays the message shown in Figure 69. If a DIMM
failure occurs, note which DIMM needs replacement based on the display.
Figure 69: CLI screen display indicating which DIMM failed
Also see the HP StorageWorks HSG60 and HSG80 Array Controller and Array
Controller Software Troubleshooting Guide for cache policy information to
determine which cache module and DIMM are at fault.
Additional information is available in the section entitled, “Upgrading cache
memory” which starts on page 245.
1.%CER--DebugTop> --18-MAY-2004 10:50:47-- Cache module DIMM 2
failed
2.%EVL--DebugTop> --18-MAY-2004 10:50:58-- Instance Code: 02623801
(not yet reported to host)
DIMM Instance Code
DIMM-1 = 02613801
DIMM-2 = 02623801
DIMM-3 = 02633801
DIMM-4 = 02643801