HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
216 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Handling RAIDset containers with at least one unit above the container
(recommended offline method)
Note: Although the above procedures are recommended for repairing RAIDsets, you
can also use the procedures described inManually manipulating disk devices
needing repair (alternative procedure).”
If any RAIDset shows a status of Maintenance Recommended, and the
RAIDset is currently associated with a unit (including a unit above a partition),
the ACS V8.8-1 upgrade process provides an in-controller memory correction for
any deficiency attributed to the metadata for the RAIDset. Although you can use
this unit indefinitely with the metadata corrections applied only to the
in-controller memory, HP recommends that during the maintenance window you
take the units off the container, invoke the following CLI command with the
PARTITION or NONPARTITION qualifier on the container, as appropriate:
REINITIALIZE container-name SPECIAL_FUNCTION_ONE=
After you issue the above command, add the unit back onto the container. This
maintenance command (if a unit is not present on the container) forces an update
of the metadata onto the disks of the container.
Note: If you decide to physically remove the members of a RAIDset and place them
into another subsystem running ACS V8.7-
x
or V8.6, and that RAIDset currently
shows a status of Maintenance Recommended, it is essential that you perform the
REINITIALIZE
container-name CLI command before removing devices in the
container from the ACS V8.8-1 subsystem.
Manually manipulating disk devices needing repair (alternative procedure)
To manually manipulate and repair disk devices where their status indicates,
MAINTENANCE RECOMMENDED: