Upgrading the Subsystem
218 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 97: Example showing the unit affected
2. From the controller on which the unit is online, issue the following command:
HSG> REINITIALIZE raidset SPECIAL_FUNCTION_ONE=INFO
See Figure 98 for an example. Note that in Figure 98 Unit D7 indicates
Un-unpartitioned, and device DISK20200 indicates Marked
partitioned: Yes. This combination of partition information indicates
that a discrepancy exists on the unit.
HSG_TOP> SHOW R1
Name Storageset Uses Used by
R1 raidset DISK10200 D7
DISK20200
DISK30200
Switches:
POLICY (for replacement) = BEST_PERFORMANCE
RECONSTRUCT (priority) = NORMAL
CHUNKSIZE = 256 blocks
State:
NORMAL
DISK20200 (member 0) is NORMAL
DISK10200 (member 1) is NORMAL
DISK30200 (member 2) is NORMAL
Size: 16751956 blocks