HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
219HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 98: Example of a device showing inconsistent metadata attributes that differ
from the attributes of the container
3. Identify which specific disk device needs repair. Ensure that it is a fully
normalized RAIDset.
HSG_TOP> REINITIALIZE R1 SPECIAL_FUNCTION_ONE=INFO
Unit: D7, Type: Un-partitioned
Raidset: R1
Device: DISK10200, Marked partitioned: No, Structure version
Affected: No, mdata_version (vsi): 11
Device: DISK30200, Marked partitioned: No, Structure version
Affected: No, mdata_version (vsi): 11
Device: DISK20200, Marked partitioned: Yes, Structure version
Affected: Yes, mdata_version (vsi): 11