Upgrading the Subsystem
225HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Handling concatenated storagesets with RAIDset containers needing
repair
Figure 102 on page 225 shows an example of the steps that must be taken in order
to clean up a RAIDset member of a concatenated storageset. This example shows
units D1, C1, R1, and R2 (the added member) with the affected RAIDset
containers. During this check, verify that no reconstructs are in progress.
Figure 102: Example of cleanup operations for RAIDset members of a concatenated
storageset
Note: Although the above procedures are recommended for repairing RAIDsets, you
can also use the procedures described inRepairing disk devices (offline and
alternative methods)” on page 215.
HSG80T> DEL D1
HSG80T> DEL C1
HSG80T> REINITIALIZE R1 SPECIAL_FUNCTION_ONE=NOPARTITION
HSG80T> REINITIALIZE R2 SPECIAL_FUNCTION_ONE=NOPARTITION
HSG80T> ADD UNIT D1 R1 DISABLE=ALL
HSG80T> ADD CONCAT C1 R1
HSG80T> SET C1 ADD=R2
HSG80T> SET UNIT D1 ENABLE