HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
229HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Figure 106: Screen display showing host information
ACS V8.7 has a switch used to modify the behavior of persistent reservations.
Because this switch does not exist in V8.6, it is removed from all connections
that have it defined if you downgrade to V8.6-1. A screen is displayed (see
Figure 107) if there are connections using the new persistent reservation style,
and you are given the opportunity to exit before continuing. This is the final
opportunity to exit the program before the downgrade occurs.
Figure 107: Screen display showing connections and reservation and providing
final opportunity to exit the downgrade process
The following host information will be lost during this downgrade:
You can exit if you need to reconfigure your systems or record this information.
Do you want to continue the downgrade procedure (Y/ [N])?
Name
--------
Host Id
-------------------
Adapter Id
-------------------
Control
-------
Port
----
Offset
------
RStyle
------
Alpha1 0123-4567-8901-1234 0123-4567-8901-1234 this 1 0 Std
NtSrv05 9876-5432-0543-1234 9876-5432-0543-1234 this 1 0 Std
The following connections will have the reservation style changed:
You can exit if you need to reconfigure your systems or record this information.
Do you want to continue the downgrade procedure (Y/ [N])?
Name
------
Host Id
-------------------
Adapter Id
-------------------
Control
-------
Port
----
Offset
------
RStyle
------
Alpha2 1003-4527-8001-1434 1003-4527-8001-1434 this 1 0 HBA
NtSrv 2106-5432-0543-1234 2106-5432-0543-1234 this 1 0 HBA