HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
231HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Installing, deleting, and listing software patches by using CLCP
Use CLCP to manage software patches. These small programming changes are
placed into the controller non-volatile memory and become active upon restarting
the controller.
Consider the following points while installing or deleting patches:
Patches are associated with specific software versions. CLCP verifies the
patch against the currently installed version.
Patches are sequential; patch one must be entered before patch two, and so on.
Deleting one patch also deletes all higher-numbered patches. For example,
deleting patch two automatically deletes patches three, four, and so on.
Controllers in a dual-redundant configuration must have the same patches.
Install patches into each controller separately.
Installing a software patch
Use the following steps to install a software patch:
1. Obtain the patch file from a customer service representative or the Internet at
http://h18006 .www1.hp .com/products/storag e w o rks/acs/index.html
.
2. Connect a PC or terminal to the controller maintenance port.
3. From the host console, quiesce all port activity.
4. Start CLCP with the following command:
RUN CLCP
The Code Load & Patch local program Main Menu is displayed (see
Figure 109).
Figure 109: Code Load & Patch local program Main Menu
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Controller Code LOAD utility
2: Enter Controller Code PATCH utility
3: Enter EMU Code LOAD utility
Enter option number (0..3) [0] ?