HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
232 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
5. Enter option 2.
The Code Patch Main Menu is displayed (see Figure 110).
Figure 110: Code Patch Main Menu
6. Enter option 1.
The Code Patch Option screen is displayed (see Figure 111).
Figure 111: Code Patch Option screen
7. Enter Y(es), and then follow the on-screen prompts.
8. After the patch is installed, press the controller Reset button to restart the
controller.
9. For dual-redundant controller configurations, repeat step 2 (on page 231)
through step 8 for the second controller.
You have selected the Code Patch local program. This program is used to
manage software code patches. Select an option from the following list:
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Code Patch Main Menu
0: Exit
1: Enter a Patch
2: Delete Patches
3: List Patches
Enter option number (0..3) [0] ?
This is the Enter a Code Patch option. The program prompts you for the
patch information, one line at time. Be careful to enter the information
exactly as it appears on the patch release. Patches may be installed for
any version of software; however, patches entered for software versions
other than XXXXX are not applied until the matching version of software
is installed.
To enter any patch, you must first install all patches with lower patch
numbers than the patch you are entering, beginning with patch number 1,
for a specific software version. If you incorrectly enter the patch
information, you are given the option to review the patch one line at a
time.
Type ^Y or ^C (then RETURN) at any time to abort Code Patch.
Do you wish to continue (y/n) [y] ?