HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
240 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
HSUTIL cannot install firmware on devices configured as single-disk drive
units or as members of a storageset, spareset, or failedset. If installing
firmware on a device previously configured as a single-disk drive, delete the
unit number and storageset name associated with it.
During the installation, the source disk drive is not available for other
subsystem operations.
Some devices might not reflect the new firmware version number when
viewed from the “other controller” in a dual-redundant controller
configuration. If this occurs, enter the following CLI command:
CLEAR_ERRORS device-name UNKNOWN.
Do not issue any CLI commands that access or inspect devices that are being
formatted.
Use the following steps to upgrade firmware with HSUTIL:
1. Connect a PC or terminal to the controller maintenance port that accesses the
device being upgraded.
2. Configure a single-disk unit.
Note: In the next steps, the firmware image is copied to this unit, and
HSUTIL
distributes it to the devices being upgraded. This unit must be a newly initialized disk
with no label or file structure to ensure that the firmware image resides in contiguous
blocks starting from LBN 0 or another known LBN. Additionally, write-back caching
must be disabled.
3. Copy the firmware image to the single-disk unit configured in step 2. The
firmware image must begin at a known LBN—usually 0—and must be
contiguous.
See the documentation that accompanied the host operating system for
instructions on copying firmware images to a disk drive.
Caution: Quiesce the host load before running
HSUTIL
; otherwise, damage to
the storage device can occur.