HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Upgrading the Subsystem
241HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
4. Start HSUTIL with the following command:
RUN HSUTIL
The HSUTIL Main Menu is displayed (see Figure 121).
Figure 121: HSUTIL Main Menu
5. Enter option 2.
6. Choose the single-disk unit as the source disk for the download.
7. Enter the starting LBN of the firmware image—usually LBN 0.
8. Enter the product ID of the device being upgraded. This ID corresponds to the
product information reported in the Type column when issuing a
SHOW DISK
FULL command.
HSUTIL lists all devices that correspond to the product ID entered.
9. Enter the disk or tape name of the device being upgraded.
10. Confirm or enter the byte count of the firmware image.
11. Confirm the download.
12. Some disk firmware releases require reformatting the disk after upgrading its
firmware. See the documentation that accompanied the firmware to determine
if device reformatting is required.
13. After HSUTIL finishes downloading the firmware, it displays the new
firmware revision for the disk drive.
HSUTIL Main Menu:
0. Exit
1. Disk Format
2. Disk Device Code Load
3. Tape Device Code Load
4. Disaster Tolerance Backend Controller Code Load
Enter function number: (0:4) [0]?