HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Controller and Cache Replacement Troubleshooting
260 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Resolution
(continued)
e. After restoring defaults, complete the instructions for installing a
controller in the “
Installing array controllers in dual-redundant
controller configurations
” section that starts on page 126.
f. Return controller pair to service.
Table 16: Resolving a failed cache error message (event 2) (continued)
Details