HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
53HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
4. Press Enter or Return.
The CLI prompt appears, indicating that a local connection was established
with the array controller.
Note: The default data transfer rate of a new HSG80 array controller using ACS V8.6
and earlier is 9600 baud. (The default data transfer rate for controllers using ACS
V8.7 may be set at 19200.) The maximum transfer rate is 19200. If the current
configuration uses 19200, use step 5 to establish this rate. See the note starting on
page 50 and the tip on page 51 for details on baud rate settings.
5. Complete the following steps if you want to increase the data transfer rate to
19200 baud:
a. Enter one of the following commands:
SET THIS_CONTROLLER TERMINAL_SPEED=19200
SET OTHER_CONTROLLER TERMINAL_SPEED=19200
b. Configure the terminal emulation software for 19200 baud.
Tip: If you are entering CLI commands in a dual-redundant configuration, remember
that the array controller connected to is “this controller” and the remaining array
controller is the “other controller.