HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
61HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Note: After fully seated, the controller starts automatically—the Reset LED turns on.
A controller restart can take as long as 60 seconds, indicated by the temporary
cycling of the port LEDs and a flashing Reset button.
Note: If the controller did not restart, use the following steps:
a. Press and hold the controller Reset button.
b. Reseat the controller program card.
c. Release the Reset button.
6. Connect a PC or terminal to the controller maintenance port.
7. From the CLI prompt, display details about the configured controller using
the following command:
SHOW THIS_CONTROLLER FULL
8. Set the date and time using the following command:
SET THIS_CONTROLLER TIME=dd-mm-yyyy:hh:mm:ss
9. Connect all host bus cables to the controller.
10. Mount the logical units on the host.
11. If using a Windows 2000 or Windows NT platform, restart the server.
12. Disconnect the PC or terminal from the controller maintenance port.
Replacing a GLM in dual-redundant controller configurations
Use the steps inRemoving a GLM” and “Installing a GLM” to replace a GLM in
dual-redundant controller configurations.
.
Caution: Static electricity can easily damage a controller or GLM. Wear a
snug-fitting, ESD wrist strap.