HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide (EK-G80MS-SA. C01, March 2005)

Common Replacement Information and Procedures
67HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software
Maintenance and Service Guide
Replacing a fiber optic cable, switch, or hub
This section details how to replace a fiber optic cable, switch, or hub.
Removing a fiber optic cable, switch, or hub
Use the following steps to remove a fiber optic cable connected to either side of
your switch or hub, or to remove the switch or hub:
1. Shut down the host system (refer to applicable host documentation for more
details).
2. Shut down the array controllers:
In single-controller configurations, shut down “this controller” with the
following command:
SHUTDOWN THIS_CONTROLLER
In dual-redundant controller configurations, shut down the “other
controller” first, and then shut down “this controller” with the following
commands:
SHUTDOWN OTHER_CONTROLLER
SHUTDOWN THIS_CONTROLLER
Note: After the array controllers shut down, the Reset buttons and the first three LEDs
turn on (see Figure 23). This can take several minutes, depending on the amount of
data that needs to be flushed from the cache modules.
Proceed only after the Reset buttons stop flashing and remain solid.
Figure 23: Reset button and first three LEDs
1 Reset button
2 First three LEDs
123456
5021
1
2